top of page
c83b03_8920cdded5874480a37b6c576e7a98fa (1)_edited.png

Insulation

DuPont™ Styrofoam™ Brand Roofmate™ XPS Insulation

DuPont™ Styrofoam™ Brand Roofmate™ XPS Insulation

DuPont™ Styrofoam™ Brand Roofmate™ XPS Insulation

Water-Resistant Insulation for Protected Membrane Roofing Systems

U.S. HFC Regulation Compliant Formulation


DuPont™ Styrofoam™ Brand Roofmate™ Extruded Polystyrene (XPS) Insulation is designed for installation above waterproofing or roofing membranes in protected membrane roof (PMR) or green roof applications and is easy to fabricate into various sizes and shapes to meet specific design needs.


Engineered for use on heavyweight decks (e.g. reinforced concrete) with a ballast layer of gravel or concrete slabs, Styrofoam™ Brand Roofmate™ XPS Insulation helps the roof membrane maintain a steady temperature, minimizing the harmful effects of freeze-thaw cycles, weathering and physical damage during and after construction.


Specifications

Standard Sizes

Thickness

Width

Length

R-Value

Edge Treatment

1 in.

2 ft.

8 ft.

5

Butt Edge

2 in.

2 ft.

8 ft.

10

Butt Edge

3 in.

2 ft.

8 ft.

15

Butt Edge

4 in.

2 ft.

8 ft.

20

Butt Edge

Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local DuPont Sales Representative or call us at 1-866-338-7668.


Testing

Styrofoam Brand Roofmate XPS Insulation exhibits physical properties as indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD

TEST TITLE

PROPERTY

RESULTS

FIRE

UL 723

Test Method for Surface Burning Characteristics of Building Materials

Surface Burning Characteristics

Flame Spread ≤ 25

Smoke Developed ≤ 450

THERMAL

ASTM C518

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Thermal Resistance per inch @ 75°F mean temp1

5.0 ft2

•h•°F/Btu, R-value, min.

ASTM D696

Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between −30°C and + 30°C with a Vitreous Silica Dilatometer

Coefficient of Linear Thermal Expansion

3.5 x 10-5

in/in•°F

ASTM D2126

Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging

Change in Dimensions

2.0 % change, max.

STRENGTH

ASTM D1621

Standard Test Method for Compressive Properties of Rigid Cellular Plastics

Compressive Strength2

40 psi, min.

ASTM C203

Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation

Flexural Strength

60 psi, min

WATER

ASTM C272

Standard Test Method for Water Absorption of Core Materials for Sandwich Construction

Water Absorption

0.1 % by volume, max.

ASTM E96

Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials

Water Vapor Permeance3

1.0 perm, max.

1Values are consistent with the criteria of ASTM C578 and the requirements of the FTC R-value rule (16 CFR Part 460). R means resistance to heat flow. The higher the R-value, the greater the insulating power.

2Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first. Since Styrofoam Brand Extruded Polystyrene Foam Insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep and fatigue deformation.

3Based on 1” thickness.


Code Compliance

Styrofoam Brand Roofmate XPS Insulationcomplies with the following codes:

Code

Description

US Product Listings & Verifications

Factory Mutual Approved


International Residential Code (IRC) and International Building Code (IBC) ICC-ES ESR-4755


Underwriters Laboratories, Inc. (UL) Classified, see Classification Certificate D-369

Regional Code Listings & Reports

California Std. Reg. #CAT1535


Florida Building Code-FL38732


Miami Dade County Approved


bottom of page