top of page
c83b03_8920cdded5874480a37b6c576e7a98fa (1)_edited.png

Insulation

DuPont™ Styrofoam™ Brand Panel Core 20 Freezer XPS Insulation

DuPont™ Styrofoam™ Brand Panel Core 20 Freezer XPS Insulation

DuPont™ Styrofoam™ Brand Panel Core 20 Freezer XPS Insulation

High Performance Insulation for Walk-In Coolers and Freezers

U.S. HFC Regulation Compliant Formulation


DuPont Styrofoam Brand Panel Core 20 Freezer Extruded Polystyrene (XPS) Insulation was designed specifically for the walk-in cooler industry meeting specific regulations for this high performance market. It consists of a closed-cell, high performance core material featuring a proprietary extrusion process facilitating precise control of parameters like density, cell size and cell orientation. This process yields foam boards that can stand up to the most demanding and extensive array of composite panel applications.


Styrofoam Brand Panel Core 20 Freezer XPS Insulation is supplied in sheets that have been carefully engineered and planed to precise tolerances for an exceptional bonding surface. Its closed-cell structure resists absorption of water, which helps maintain panel integrity and insulating properties in low temperature applications and other environments with high humidity and moisture conditions. It also resists adhesive absorption, requiring less glue for effective and lasting adhesion of facer materials.


Specifications

Testing

Styrofoam Brand Panel Core 20 Freezer XPS Insulation exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD

TEST TITLE

PROPERTY

RESULTS

FIRE

UL 723

Test Method for Surface Burning Characteristics of Building Materials

Surface Burning Characteristics

Flame Spread ≤ 25

Smoke Developed ≤ 450

THERMAL

ASTM C518

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Thermal Resistance per inch: fresh @ 55 °F (13° C) min. fresh @ 20 °F (-7 °C) min.1

7.2 ft2•h•°F/Btu, R-value, min.

8.0 ft2•h•°F/Btu, R-value, min.

ASTM D696

Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between −30°C and + 30°C with a Vitreous Silica Dilatometer

Coefficient of Linear Thermal Expansion

3.5 x 10-5

in/in•°F

ASTM D2126

Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging

Change in Dimensions

2.0% change, max.

STRENGTH

ASTM D1621

Standard Test Method for Compressive Properties of Rigid Cellular Plastics

Compressive Strength2

20 psi, min.

ASTM C203

Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation

Flexural Strength

40 psi, min., extruded

ASTM C203

Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation

Flexural Modulus

1,500 psi, min., extruded

ASTM D1623

Standard Test Method for Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics

Tensile Strength

50 psi, min., vertical

ASTM C273

Standard Test Method for Shear Properties of Sandwich Core Materials

Shear Strength

25 psi, min.

ASTM C273

Standard Test Method for Shear Properties of Sandwich Core Materials

Shear Modulus

300 psi, min.

WATER

ASTM C272

Standard Test Method for Water Absorption of Core Materials for Sandwich Construction

Water Absorption

0.1% by volume, max.

ASTM E96

Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials

Water Vapor Permeance3

1.5 perm, max.

1R means resistance to heat flow. The higher the R-value, the greater the insulating power.

2Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first. Since Styrofoam Brand Extruded Polystyrene Foam Insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep and fatigue deformation.

3Based on 1” thickness.


Code Compliance

Styrofoam Brand Panel Core 20 Freezer XPS Insulation complies with the following codes:

Code

Description

US Product Listings & Verifications

Underwriters Laboratories, Inc. (UL) Classified, see Classification Certificate D-369

Regional Code Listings & Reports

California Std. Reg. #CA T1535