top of page
c83b03_8920cdded5874480a37b6c576e7a98fa (1)_edited.png

Insulation

DuPont™ Styrofoam™ Brand Highload 60 XPS Insulation

DuPont™ Styrofoam™ Brand Highload 60 XPS Insulation

DuPont™ Styrofoam™ Brand Highload 60 XPS Insulation

Subfloor Thermal Insulation for Low-Temperature Applications

U.S. HFC Regulation Compliant Formulation


DuPont™ Styrofoam™ Brand Highload 60 Extruded Polystyrene (XPS) Insulation is a closed-cell foam insulation designed for demanding applications such as low-temperature (freezer floor) applications, highways, airport runways, bridge abutments, parking decks, utility lines, and ice rinks. With a compressive strength of 60 psi (415 kPa), it offers exceptional moisture resistance and R-value retention.


Styrofoam™ Brand Highload Insulation products are engineered to resist compressive creep and fatigue, ensuring sustained compressive strength over time. Like all Styrofoam™ Brand insulation products, Highload 60 XPS Insulation is known for its durability, versatility, and reusability, making it a preferred choice for a wide range of high-load applications.


Specifications

Standard Sizes

Thickness

Width

Length

R-Value

Edge Treatment

1 in.

2 ft.

8 ft.

5

Square Edge

1 1/2 in.

2 ft.

8 ft.

7.5

Square Edge

2 in.

2 ft.

8 ft.

10

Square Edge

3 in.

2 ft.

8 ft.

15

Square Edge

3 1/2 in.

2 ft.

8 ft.

17.5

Square Edge

2 in.

4 ft.

8 ft.

10

Square Edge

3 in.

4 ft.

8 ft.

15

Square Edge

4 in.

4 ft.

8 ft.

20

Square Edge

Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact your local DuPont Sales Representative or call us at 1-866-338-7668.


Testing

Styrofoam Brand Highload 60 XPS Insulation exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact DuPont at 1-833-338-7668 when additional guidance is required for writing specifications that include this product.

TEST METHOD

TEST TITLE

PROPERTY

RESULTS

FIRE

UL 723

Test Method for Surface Burning Characteristics of Building Materials

Surface Burning Characteristics

Flame Spread ≤ 25

Smoke Developed ≤ 450

THERMAL

ASTM C518

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Thermal Resistance per inch, @ 75°F mean temp.1

5.0 ft2

•h•°F/Btu, R-value, min.

ASTM D696

Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between −30°C and + 30°C with a Vitreous Silica Dilatometer

Coefficient of Linear Thermal Expansion

3.5 x 10-5

in/in•°F

ASTM D2126

Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging

Change in Dimensions

2.0 % change, max.

STRENGTH

ASTM D1621

Standard Test Method for Compressive Properties of Rigid Cellular Plastics

Compressive Strength2

60 psi, min.

ASTM D1622

Standard Test Method for Compressive Properties of Rigid Cellular Plastics

Compressive Modulus (typical)

2,200 psi

ASTM C203

Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation

Flexural Strength

75 psi, min

WATER

ASTM C272

Standard Test Method for Water Absorption of Core Materials for Sandwich Construction

Water Absorption

0.1 % by volume, max.

ASTM E96

Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials

Water Vapor Permeance3

0.8 perm, max.

1Values are consistent with the criteria of ASTM C578 and the requirements of the FTC R-value rule (16 CFR Part 460). R means resistance to heat flow. The higher the R-value, the greater the insulating power.

2Vertical compressive strength is measured at 5 percent deformation or at yield, whichever occurs first. Since Styrofoam insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep. For static loads, 3:1 is suggested. For dynamic loads, call 1-866-583-2583 for safety factor recommendation.

3Based on 1” thickness.


Code Compliance

Styrofoam Brand Highload 60 XPS Insulation complies with the following codes:

Code

Description

US Product Listings & Verifications

Factory Mutual Approved


International Residential Code (IRC) and International Building Code (IBC); see ICC-ES ESR-4755


Underwriters Laboratories, Inc. (UL) Classified, see Classification Certificate D-369

Regional Code Listings & Reports

California Std. Reg. #CA T1535


bottom of page