top of page
c83b03_8920cdded5874480a37b6c576e7a98fa (1)_edited.png

Insulation

DuPont™ Styrofoam™ Brand Plazamate™ XR XPS Insulation

DuPont™ Styrofoam™ Brand Plazamate™ XR XPS Insulation

DuPont™ Styrofoam™ Brand Plazamate™ XR XPS Insulation

High R-value, Tough, Versatile Insulation for Commercial Roof, Low-Temp, and Geotechnical Applications.

U.S. HFC Regulation Compliant Formulation


DuPont Styrofoam Brand Plazamate XR Extruded Polystyrene (XPS) Insulation is next generation in evolution of high-performance closed cell insulation that allows extra design flexibility for architects and engineers by optimizing roof thickness – reducing expensive commercial roof building alterations required for meeting the latest building and energy codes – and assists in reducing overall project costs. Styrofoam Brand Plazamate XR XPS Insulation is reusable, moisture-resistant, durable, easy to work with and offers more R-value per inch.


Styrofoam Brand Plazamate XR XPS Insulation, with a compressive strength of 60 psi (415 kPa), stands out for its strong moisture resistance and R-value retention. It's designed to resist compressive creep and fatigue, ensuring long-term structural integrity and thermal performance. This insulation is ideal for wet and exposed applications, including plaza decks and roof insulation.


Specifications

Standard Sizes

Thickness

Width

Length

R-Value

Edge Treatment

2 1/4 in.

4 ft.

8 ft.

15

Square Edge

3 in.

4 ft.

8 ft.

20

Square Edge

Note: Please be advised that additional sizes may be available. Availability of all sizes varies by region and is subject to change. For further information, please contact us.


Testing

Styrofoam Brand Plazamate XR XPS Insulation exhibits the properties and characteristics indicated in the table below when tested as represented. Review all instructions and (Material) Safety Data Sheet ((M)SDS) before use. Please contact us when additional guidance is required for writing specifications that include this product.

TEST METHOD

TEST TITLE

PROPERTY

RESULTS

FIRE

UL 723

Test Method for Surface Burning Characteristics of Building Materials

Surface Burning Characteristics

Flame Spread ≤ 25

Smoke Developed ≤ 450

THERMAL

ASTM C518

Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus

Thermal Resistance per inch @ 75°F mean temp1

6.7 ft2

•h•°F/Btu, R-value, min.

ASTM D696

Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between −30°C and + 30°C with a Vitreous Silica Dilatometer

Coefficient of Linear Thermal Expansion

3.5 x 10-5

in/in•°F

ASTM D2126

Standard Test Method for Response of Rigid Cellular Plastics to Thermal and Humid Aging

Change in Dimensions

0.9 % change, max.

STRENGTH

ASTM D1621

Standard Test Method for Compressive Properties of Rigid Cellular Plastics

Compressive Strength2

60 psi, min.

ASTM C203

Standard Test Methods for Breaking Load and Flexural Properties of Block-Type Thermal Insulation

Flexural Strength

75 psi, min

WATER

ASTM C272

Standard Test Method for Water Absorption of Core Materials for Sandwich Construction

Water Absorption

0.01 % by volume, max.

ASTM E96

Standard Test Methods for Gravimetric Determination of Water Vapor Transmission Rate of Materials

Water Vapor Permeance3

0.2 perm, max.

1Values are consistent with the criteria of ASTM C578 and the requirements of the FTC R-value rule (16 CFR Part 460). R means resistance to heat flow. The higher the R-value, the greater the insulating power.

2Vertical compressive strength is measured at 10 percent deformation or at yield, whichever occurs first. Since Styrofoam Brand Extruded Polystyrene Foam Insulations are visco-elastic materials, adequate design safety factors should be used to prevent long-term creep and fatigue deformation.

3Based on 1” thickness.

bottom of page